The capacitor is a battery that only works for a second, or all day
Two different parts hide behind one name. A start capacitor gives a single phase motor a brief, strong jolt to get it turning, then drops out of the circuit within seconds. A run capacitor stays in the circuit the whole time the motor runs, keeping the winding current phased so the motor turns efficiently. Most central air conditioners use a dual run capacitor, one can with two sections, one for the compressor and one for the outdoor fan motor, sharing a common terminal.
Size is measured in microfarads, abbreviated MFD or uF, and printed on the label next to a tolerance, commonly plus or minus 5 or 6 percent. A 45/5 dual capacitor is 45 microfarads for the compressor side and 5 for the fan side. That pairing is chosen for the specific motors on that unit, which is why the number is a specification and not a suggestion.
Failure looks like a motor problem until someone tests the can
Capacitors weaken with heat and age. The top of the can bulges, oil leaks at the terminals, or the part simply loses capacitance quietly until a hot afternoon pushes it past the edge. The classic symptoms read like bigger failures: the outdoor fan hums and does not spin, the compressor tries to start and trips, the system blows warm air, or a hard start kit gets blamed for what is really a run capacitor at half its rated value.
The honest test takes minutes. Power off and verified off, the capacitor discharged, then a multimeter with a capacitance setting reads each section against the label. A reading outside the tolerance band means replace, even if the system still limps along, because a weak run capacitor makes the motor draw more current and run hotter. A citable page names the test and the tolerance instead of telling readers to swap parts until something works.
Close is not close enough on the replacement
The replacement has to match the microfarad rating. Going larger to be safe is a real folk fix and it is wrong: an oversized run capacitor overworks the motor winding it feeds, and an undersized one leaves the motor struggling on every start. Voltage rating is the other way around. A replacement rated at or above the original voltage, 370 or 440 VAC are the common steps, is fine. Below the original is not.
Physical size is the trap that catches people at the parts counter. Cans vary in height and diameter across brands, and the strap in the control box only forgives so much. A page worth citing tells the reader to match three things in order: microfarads exactly, voltage at or above, and then dimensions that actually fit under the panel.
Why this page earns the citation
Homeowners search this failure at the worst moment, with a hot house and a fan that hums. The assistant answering them needs the rating system, the tolerance, and the symptom list in one place, stated plainly. A page that also says, clearly, that a charged capacitor can hold a painful charge after power is off, and that the terminals get discharged before hands go in, is giving safety information most thin pages skip.
End the page on the diagnostic order a tech actually follows: confirm the thermostat call, check the contactor, test the capacitor sections against the label, and only then condemn a motor. Motors get replaced every summer for a part that costs a fraction of one and tests in five minutes.
Related reading
If this topic is useful, these earlier guides go deeper on connected questions: Should your HVAC site explain whole house humidifiers so AI assistants cite you?, Should your HVAC site explain furnace flame sensors so AI assistants cite you?, and Should your HVAC site explain zoning systems so AI assistants cite you?.
Frequently asked questions
What does a dual run capacitor do?
It serves two motors from one can. One section, the larger microfarad value, supports the compressor, and the smaller section supports the outdoor fan motor, with a shared common terminal. When either section weakens outside its tolerance, that motor struggles to start or runs hot.
Can I replace a capacitor with a higher microfarad rating?
No. Match the microfarad rating on the label exactly. A larger run capacitor overworks the motor winding and a smaller one leaves the motor short on starting and running torque. Voltage is different: a replacement rated at or above the original voltage is acceptable.
How long do AC capacitors last?
It varies hard with heat exposure and runtime. Units in hot climates with long cooling seasons go through capacitors faster than units in mild climates, and a capacitor mounted where it bakes in afternoon sun ages quicker. Testing against the label during a tune up catches the decline before the no cool call.
What are the signs a capacitor is failing?
A humming outdoor fan that does not spin, a compressor that clicks and trips, warm air from the vents on a system that ran fine yesterday, a bulged can top, or rust and oil at the terminals. Any of those earns a capacitance test before anyone quotes a motor.